Copper Conductor (IEC 502) - Rated Voltage
1.8/3.0 - 18/30 kV |
|
|
|
|
|
|
|
| |
|
XLPE Insulation |
Cross Section |
|
| |
PVC Sheath |
PE Sheath |
|
| |
Twisted Aerial Cables |
NF2XSEY |
NF2XSE2Y |
up to 18/30 kV: |
|
| |
2-4 cores |
50-120 |
|
| |
2-3 cores |
NF2XSEY-T |
NF2XSE2Y-T |
up to 18/30 kV: |
|
| |
+ steel messenger |
(50-150)+50 |
|
| |
Single Core |
N2XSY |
N2XS2Y |
up to |
|
| |
+ copper tape screen |
6/10kV: 25-630 |
|
| |
+ copper wire screen |
N2XCY |
N2XC2Y |
12/20kV: 35-630 |
|
| |
+ copper tape screen |
N2XSEKY |
N2XSEK2Y |
18/30kV: 50-630 |
|
| |
+ lead sheath |
|
|
| |
Three Cores with individual
copper
tape
screen
and PVC core covering |
N2XSEY |
N2XSE2Y |
up to |
|
| |
+ steel round wire armor |
N2XSERGbY |
N2XSERGb2Y |
6/10kV: 25-300 |
|
| |
+ steel flat wire armor |
N2XSEFGbY |
N2XSEFGb2Y |
12/20kV: 35-300 |
|
| |
+ double steel or aluminum tape armor |
N2XSEBY |
N2XSEB2Y |
18/30kV: 50-300 |
|
| |
+ lead sheath |
N2XSEKY |
N2XSEK2Y |
|
|
| |
+ lead sheath |
N2XSEKBY |
N2XSEKB2Y |
up to |
|
| |
+ double steel or aluminum tape armor |
6/10kV: 25-95 |
|
| |
+ lead sheath |
N2XSEKRGbY |
N2XSEKRGb2Y |
12/20kV: 35-95 |
|
| |
+ steel round wire armor |
18/30kV: 50-95 |
|
| |
+ lead sheath |
N2XSEKFGbY |
N2XSEKFGb2Y |
|
|
| |
+ steel flat wire armor |
|
|
|
|
|
|
|
|
|
|
Aluminum Conductor (IEC 502) - Rated Voltage
1.8/3.0 - 18/30 kV |
|
|
|
|
|
|
|
| |
|
XLPE Insulation |
Cross Section |
|
| |
PVC Sheath |
PE Sheath |
|
| |
Twisted Aerial Cables |
NFA2XSEY |
NFA2XSE2Y |
up to 18/30 kV: |
|
| |
2-4 cores |
50-120 |
|
| |
2-3 cores |
NFA2XSEY-T |
NFA2XSE2Y-T |
up to 18/30 kV: |
|
| |
+ steel messenger |
(50-150)+50 |
|
| |
Single Core |
NA2XSY |
NA2XS2Y |
up to |
|
| |
+ copper tape screen |
6/10kV: 25-630 |
|
| |
+ copper wire screen |
NA2XCY |
NA2XC2Y |
12/20kV: 35-630 |
|
| |
+ copper tape screen |
NA2XSKY |
NA2XSK2Y |
18/30kV: 50-630 |
|
| |
+ lead sheath |
|
|
| |
Three Cores with individual
copper |
NA2XSEY |
NA2XSE2Y |
up to |
|
| |
tape screen
and PVC core covering |
6/10kV: 25-300 |
|
| |
+ steel round wire armor |
NA2XSERGbY |
NA2XSERGb2Y |
12/20kV: 35-300 |
|
| |
+ steel flat wire armor |
NA2XSEFGbY |
NA2XSEFGb2Y |
18/30kV: 50-300 |
|
| |
+ double steel or aluminum tape armor |
NA2XSEBY |
NA2XSEB2Y |
|
|
| |
+ lead sheath |
NA2XSEKY |
NA2XSEK2Y |
|
|
| |
+ lead sheath |
NA2XSEKBY |
NA2XSEKB2Y |
up to |
|
| |
+ double steel or aluminum tape armor |
6/10kV: 25-95 |
|
| |
+ lead sheath |
NA2XSEKRGbY |
NA2XSEKRGb2Y |
12/20kV: 35-95 |
|
| |
+ steel round wire armor |
18/30kV: 50-95 |
|
| |
+ lead sheath |
NA2XSEKFGbY |
NA2XSEKFGb2Y |
|
|
| |
+ steel flat wire armor |
|
|
| |
|
|
|
|
|
|